|
|
Tripp-Lite 6000VA Rackmount 9U Double-Conversion Online Rackmount/Tower UPS + Step-Down Transformer + Battery Pack, Refurbished (SU6000RT3U)
|
Out of stock
Manufacturer: Tripplite
Manufacturer Part No: SU6000RT3U
|
This is a refurbished Uninterruptible Power Supply/Battery Backup unit. It has been installed with brand new, high quality batteries, and has been thoroughly tested and then professionally packed in a brand new box. All products sold by UPSforLESS are fully covered for all parts and labor by our famous One-Year "No-Hassle" warranty and our innovative 30-Day "Lemon" warranty.
FEATURES
- True on-line, double conversion UPS provides pure, sine wave AC output at all times
- Maintains continuous operation through blackouts, voltage fluctuations and surges with zero transfer time
- Removes harmonic distortion, electrical impulses, frequency variations and other hard to solve power problems
- 6000VA/4200 watt power capacity with hardwire input/output connections
- Accepts input voltages between 156 and 276, regulating output within 2% of selectable 208 and 120V AC output
- Standard included 3U battery pack provides 20 minutes runtime at half load (3000VA) and 8 minutes at full load (6000VA)
- Expandable runtime with multiple external battery packs
- Innovative design makes unit adaptable for rackmount, tower, or stacking applications
- Power module and battery pack require only 3 rack spaces each (9U total rack space usage)
- DB9 serial port for network interface; SNMP compatible
- Slot for optional SNMP/web card SNMP/Web card for accessory slot (SNMPWEBCARD)
- Fault tolerant auto-bypass maintains continuous utility output to connected equipment, even in cases where the UPS is overloaded or suffers an internal failure that requires service
- Manual bypass switch on the transformer module allows users to disconnect, remove, and replace the power module while maintaining continuous utility power to connected equipment
- Diagnostic LEDs
- Includes RJ11 EPO (emergency power off) port and interconnection cable
OUTPUT
- Output Volt Amp Capacity (VA) 6000 (4200 Watts)
- Output power factor 0.7
- Nominal Output Voltage(s) Supported 120v; 208v
- Output voltage regulation (line mode) +/- 2%
- Output voltage regulation (Economy line mode) +/- 10%
- Output voltage regulation (Battery mode) +/- 2%
- Built-in UPS output receptacles Hardwire
- Output circuit breaker 40A double-pole
- Output AC waveform Sine wave
INPUT
- Rated input current (at maximum load) 30A
- Nominal Input Voltage(s) Supported 208V AC
- UPS input connection type Hardwire
- Recommended Electrical Service 30A 208V
BATTERY
- Full load runtime (minutes) 8 min. (4200w)
- Half load runtime (minutes) 20 min. (2100w)
- Expandable battery runtime Supports extended runtime with optional external battery packs
- External battery pack compatibility BP240V10RT3U; BP240V557C-1PH; BP240V787C-1PH; BP240V1037C-1PH; BP240V1407C-1PH
- Battery recharge rate (included batteries) Less than 6 hours from 10% to 80%
- Battery replacement description Hot-swappable, user replaceable batteries
VOLTAGE REGULATION
- Voltage regulation description Online, double-conversion power conditioning
- Overvoltage correction 2% output voltage regulation during overvoltages to 276
- Undervoltage correction 2% output voltage regulation during undervoltages to 156
LEDS ALARMS & SWITCHES
- LED Indicators 6 LEDs indicate line power, online mode, economy/bypass mode, on-battery, charger and AC output status; LCD screen offers additional information and control options
- Front panel LCD display Selectable LCD display with scroll and selection buttons enables UPS control and detailed monitoring options; LED/LCD panel rotates for viewing in rack/tower formats (see manual)
- Alarms Unique audible alarms for all major UPS, environmental and power conditions (see manual)
- Alarm cancel operation Alarm cancel switch
SURGE / NOISE SUPPRESSION
- UPS AC suppression joule rating 480
- UPS AC suppression response time Instantaneous
- EMI / RFI AC noise suppression Yes
ISOLATION
- Output isolation transformer 120V output includes load isolation transfomer protection
PHYSICAL
- Primary form factor Rackmount UPS / Power Module dimensions in primary form factor (height x width x depth / inches) 5.2 x 17.5 x 26 (13.3cm x 44.4cm x 66cm)
- Installed whole system total rack space height (rack spaces) 9U
- UPS / Power Module weight (lbs) 43.8 (19.9 Kg.)
- Stepdown transformer dimensions (height x width x depth / inches) 5.2 x 17.5 x 26 (13.3cm x 44.4cm x 66cm)
- Stepdown transformer dimensions (height x width x depth / cm) Stepdown transformer weight (lbs) 90 (40.9 Kg.)
- Included battery pack dimensions (height x width x depth / inches) 5.2 x 17.5 x 25 (13.3cm x 44.4cm x 63.5cm)
- Included battery pack weight (lbs) 136.5 (62 Kg.)
ENVIRONMENTAL
- Operating Temperature Range +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
- AC mode BTU / hr. (full load) 1412.3
- AC economy mode BTU / hr. (full load) 911.5
- Battery mode BTU / hr. (full load) 1586.7
COMMUNICATIONS
- Communications interface DB9 Serial; Contact closure; EPO (emergency power off); Slot for SNMP/Web interface
- Network monitoring port description RS232 and contact closure communications are located on two separate DB9 ports
LINE / BATTERY TRANSFER
- Transfer time No transfer time (0 ms.) in online, double-conversion mode
- Low voltage transfer to battery power (setpoint) 156
- High voltage transfer to battery power (setpoint) 276
SPECIAL FEATURES
- Cold Start (startup in battery mode during a power failure) Cold-start operation supported
- High availability UPS features Automatic inverter bypass; Hot swappable UPS power module; Hot swappable batteries
- Green & high efficiency features High efficiency economy mode operation; Schedulable daily hours of economy mode operation
CERTIFICATIONS
- UPS Certifications Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Tested to CE (EU); Tested to GOST (Russia); Tested to SASO (Saudi Arabia); Tested to IRAM (Argentina); Meets FCC Part 15 Category A (EMI); ROHS (Reduction of Hazardous Substances)
|
|



| Frequently Asked Questions and links to company policies and procedures. Please don't hesitate to contact us at (866) 577-3628 if you have a question that couldn't be answered in these pages.
|
| Manufacturer specific UPS sizing and selection tools.
Once you have determined the correct size and type of UPS, please look through our stock to see if we have anything that is similar to the recommendation. |
|
|