This is a refurbished uninterruptible power supply/battery backup unit. It has been installed with brand new high-quality batteries, thoroughly tested and then professionally packed in a brand new box. All products sold by UPSforLESS are fully covered for all parts and labor by our famous one-year 'no hassle' warranty and by our equally famous 30-day 'lemon' warranty.
Technical Specifications Output
- Output Capacity: 1440 VA (1050 Watts)
- Output Voltage 120V
- Output Connections (6) NEMA 5-15R (Standard 3-prong receptacles)
- On Battery Voltage Regulation +/- 5% RMS
- Voltage Wave Shape (on battery) Sine Wave
Input
- Input Voltage 120V
- Input Connection NEMA 5-15P (Standard 3-prong plug)
- Input Voltage Range 77-152 V
- Frequency Range 46-65 Hz
Battery
- Battery Type Sealed, lead-acid; maintenance free
- Battery Replacement Hot-swappable internal batteries and external batteries modules
- Runtime at full load (1050 Watts) 6 minutes
- Runtime at half load (525 Watts) 17 minutes
- Recharge Time 3 hours to 90% usable capacity
- Start-On-Battery Allows start of UPS without utility input
General
- Diagnostics Full System self-test on power up
- Transfer Time 2-4ms typical
- Overload (normal operation) 110% overload, shutdown after 3 minutes. 150% overload, shut down 10 cycles
Physical
- Width 6.38 inches (162mm)
- Length 18.39 inches (467mm)
- Height 9.84 inches (250mm)
- Net Weight 50.7 lbs (23.0 Kg.)
Communications
- Audible Alarms For various UPS alarm conditions, including: On Battery, Low Battery, Overload, UPS fault
- Network Transient Protector UL 497 A, in/out jacks RJ45 (high voltage models network protection) & RJ11 (low voltage models modem protection)
- X-Slot Interface RS-232 Single Serial Card (standard),
- Power Management Software Available
Environmental
- Safety Certifications UL; cUL; NOM; C-Tick; CE mark
- EMC Compliance FCC Part 15, EN50091-2, Class A for 2.2 KVA and RM; Class B for 1000 and 1500 VA tower models
- Operating Temperature 0 to 40 C (32 to 104 F)
- Lightning & Surge Protection ANSI/IEEE C62.41 (IEEE 587), IEC61000-4-5
- Surge Energy Rating 480 Joules
- Audible Noise Less than 40 dBA typical
|
|