Liebert GXT2-10000RT208 10KVA Double-Conversion Online Rackmount 6U UPS, Refurbished (GXT2-10000RT208)
|
Out of stock
Manufacturer: Liebert
Manufacturer Part No: GXT2-10000RT208
|
This is a refurbished Uninterruptible Power Supply/Battery Backup unit. It has been installed with brand new, high quality batteries, and has been thoroughly tested and then professionally packed in a brand new box. All products sold by UPSforLESS are fully covered for all parts and labor by our famous One-Year "No-Hassle" warranty and our innovative 30-Day "Lemon" warranty.
The Liebert UPStation GXT 2U is a compact, true "on-line" UPS. An "on-line" UPS continuously conditions and regulates its output voltage, whether the utility power is present or not. It supplies connected equipment with clean sine wave power. Sensitive electronic equipment operates best from sine-wave power. For ease of use, the UPStation GXT 2U contains a light emitting diode (LED) display to indicate either "load percentage" or "battery capacity" depending upon the mode of operation. It also provides self-diagnostic tests, a combination On/Alarm Silence/Manual Battery Test button, a combination Off/Bypass button, user configurable program, and two levels of alarms when the unit is operational. Key Features.
Specifications
Input
- Maximum Capacity 10,000 VA (8,000 W)
- Input Voltage 208V AC
- Input Plug Hardwired Terminal Block 3W + G
- Frequency 50/60 Hz
Output
- Voltage 120, 208V AC
- Frequency 50/60 Hz
- Waveform Sinwave
- Overload 130% for 60 seconds, 200% for 5 seconds
Batteries
- Sealed lead acid rechargeable batteries.
- Replacement Battery Kit for UPS – URBCLI120912
- Replacement Battery Kit for Extended Runtime Battery Cabinet – URBCLI120924
- Runtime Chart
Runtime Rate Chart
|
(All times in minutes)
|
UPS Only
|
With 1 EBM
|
With 2 EBM's
|
With 3 EBM's
|
With 4 EBM's
|
|
Runtime at full load (8000 Watts)
|
6
|
17
|
28
|
41
|
54
|
|
Runtime at 75% load (6000 Watts)
|
10
|
24
|
41
|
58
|
76
|
|
Runtime at half load (4000 Watts)
|
16
|
39
|
66
|
92
|
119
|
|
Runtime at 25% load (2000 Watts)
|
41
|
97
|
156
|
224
|
268
|
|
Runtime at minimal load (800 Watts)
|
107
|
251
|
333
|
494
|
590
|
Physical
- Width 16.93 inches (430 mm)
- Depth 25.98 inches (660 mm)
- Height 6U, 10.5 inches (267 mm)
- Weight 118 lbs. (53.6 Kg.)
- Audible Noise <55 dBA at 1 meter
Compliance
- Safety UL1778, C-UL listed
- RFI/EMI FCC Part 15, Subpart B, Class A
- Surge IEEE/ANSI C62.41 Category A & B
|
|