This UPS is brand new. One year warranty coverage is offered directly by the manufacturer. Since warranty coverage is provided directly from Powercom, this unit is not covered by the UPSforLESS "lemon" warranty.
This line interactive UPS provides a pure sine-wave output for voltage sensitive and critical loads. The fully digitized and microprocessor controlled UPS has buck & boost automatic voltage regulation capability allowing the UPS to correct for voltage sags without needing to go to backup batteries, thus extending the life of the batteries.
Features
- Pure sine-wave output for voltage sensitive loads
- Line interactive design
- Boost and buck AVR
- Hot swappable battery
- Ability to expand runtime with addition of external rackmount battery cabinet
- Smart serial communications port
- Lightning & surge protection
- Short circuit & overload protection
- Telephone/Modem spike protection
- Site wiring fault warning
- Smart power management software included
- Load/battery display meter
- Advanced battery management
- Energy saving (sleep) mode
- Cold start without A/C power
- SNMP capability (optional)
Specifications
AC INPUT
- AC Input Capacity on Battery 3000VA
- AC Input Frequency 50/60 Hz+/-5Hz (Auto Sensing)
AC OUTPUT
- AC Output Load Capacity 1800 Watts
- Receptacles: 6 x NEMA 5-15R (standard 3-prong North American plug)
- AC Output Voltage Pure sine wave at +/-5% of nominal, -10% of nominal after low battery warning
- AC Output Voltage Regulation: AVR automatically increases output voltage if voltage drops by 9% or more. AVR automatically decreases output voltage if voltage rises by 9% or more.
PROTECTION
- Protection Spike 320 Joules, 2ms
- Protection EMI/RFI 10dB at 0.5 MHz, 50 dB at 30 MHz
- Protection Overload UPS automatical shutdown if overload exceeds 110% of nominal at 20 seconds and 125% at 5 seconds.
- Protection Transfer Time 6~8 milliseconds (typical), including detection time
BATTERY
- Battery Type Hot swappable, sealed, maintenance-free lead acid, with 3 - 6 years lifetime
- Battery Typical Recharge Time 4 hours (to 90% of full capacity)
- Battery Run Time at full load (1800 watts) – 5.5 minutes
- Battery Run Time at half load (900 watts) – 17.5 minutes
PHYSICAL
- Physical Weight 46.5 kg., 102.3 lbs
- Physical Dimension 19.0x15.0x5.1 inches, 483x38x130 mm
INDICATORS
- LCD Indicators Status indicate line, bypass, inv, backup, fault. bat capacity, load capacity, I/P frequency, O/P frequency, inside temperature, fault statuts, load
ALARMS
- Alarm Battery Backup Slow beeping sound (about 0.25 Hz)
- Alarm Battery Low Rapid beeping sound (about 1.00 Hz)
- Alarm Overload Continue beeping sound
INTERFACE
- Interface Dry Contact Sends AC fail and battery low signals, and receives shutdown signal from computer.
- Interface RS-232 Detect battery low, Schedule UPS on/off, AC input/output
- Interface Option Novell, SNMP, Windows NT, Windows 95/98/2000/ME/XP
ENVIRONMENT
- Environment Ambient 3,500 meters max. elevation, 0~95% humidity non-condensing
- Environment Audible <45dBA (1 meter from surface)
- Environment Storage Condition 15,000 meters max. elevation
|